Area “C” Keypad Options
P859E Arm key can disarm during exit - Default 1-8 Page 34
P860E Stay key can disarm during Stay armed state - Default 1-8 Page 34
Area “C” Secondary Output Options
P861E-P868E OPTIONS
P861E Area "C" secondary options for output #1 - Default 0 1 = Any bypass Page 33
P862E Area "C" secondary options for output #2 - Default 0 2 = Auto bypass warning
P863E Area "C" secondary options for output #3 - Default 0 3 = Entry beeps
P864E Area "C" secondary options for output #4 - Default 0 4 = Exit Beeps
P865E Area "C" secondary options for output #5 - Default 0 5 = Follow Full Arming
P866E Area "C" secondary options for output #6 - Default 0 6 = Follow Stay Arming
P867E Area "C" secondary options for output #7 - Default 0 7 = Follow Disarm
P868E Area "C" secondary options for output #8 - Default 0 8 = Spare
Programming Area “C” Auto Arm/Disarm Time-zones
P869E Time Zones used for Area "C" auto arming/disarming- Default 0 (see P872E) Page 34
Area “C” Miscellaneous Options 1
P870E Misc area options 1 - Default 6 1 = Cannot Arm if not sealed Page 35
2 = “Arm” required before code
3 = “Stay” required before code
4 = Code required to arm
5 = Code required to “Bypass” zones
6 = Control/Chime disables chime zones
7 = Spare
8 = Cannot arm if Supervise fail active
Area “C” Miscellaneous Options 2
P871E Misc area options 2 - Default 0 1 = Near & Verified Alarms Page 36
2 = Spare
3 = Spare
4 = Pendant chirps when armed
5 = Pendant chirps when in Stay Mode
6 = 2 sec pulse at arm
7 = 2 sec pulse at disarm
8 = Cannot Arm if System Battery is Low
Area “C” Time & Delay Options
P872E AREA "C" TIME AND DELAY OPTIONS - Default 0 Page 36
1 = Arm area When Time Zone Ends
2 = Disarm area When Time Zone Starts
3 = Disable Stay Mode Exit Delay
4 = Disable Arm Mode Exit Delay
5 = Disable Stay Mode Entry Delay
6 = Disable Arm Mode Entry Delay
7 = Use special Stay Mode entry timer
8 = Report Stay Mode alarms & Bypasses via dialler
** Dialler Reporting Options for Area “C” **
P875E Area C reporting options -Default = 1 Page 37
1 = Send arm/disarm 5 = Send arm when exit delay expires (LED On)
2 = Send Stay Mode arm/disarm 6 = Send all zone restores at disarm only
3 = Send disarm only after activation's 7 = Spare
4 = Send Stay Mode disarm only after alarm 8 = Spare
** Area “C” Contact ID Account Code **
P876E Account number for Area "C" - default 0000 Page 38
**Area “C” Arm/Disarm Reporting Scenario **
P877E Area C Arm/Disarm reports mapped to scenario 1-4 default 1 Page 38
**Area “C” Latchkey Disarm Reporting Scenario **
P878E Area C Latchkey Disarm Reporting scenario 1-4 default 1 Page 38