Page 40
ITA RECEIVED SIGNAL STRENGTH (RSSI) FOR RADIO ZONES - P709E 1-64E
RECEIVED SIGNAL STRENGTH (RSSI) FOR RADIO ZONES - P710E 1-64E
The alarm panel has the ability to display the signal strength of the received signal from individual detectors.
Please note that this feature is only available if the receiver has the RSSI signal connected. As standard the
RSSI signal is not normally available.
To eliminate confusion when multiple detectors are in operation, the panel will only display the RSSI level of a
detector that is specified at this address. The detector MUST be enrolled into the panel for this to work. The RSSI
option can be accessed from Client or Installer program modes. In Client mode, the user must have option 7 at
addresses P221E-P240E assigned to their code for them to be allowed to start the RSSI mode.
To display the RSSI level of detector number 10 press P710E10E.
Now trigger the detector and return back to the keypad. The level of the last transmission from detector number 10
will be displayed at the keypad with a reading of 1-100%. Received signals from other detectors will be ignored by
the panel during the RSSI reading.
The ITA mode at address P709E is the same as P710E with the exception that the lower limit has been raised to
approximately 30%. This means that any signals that do not exceed the 30% minimum threshold will not display any
value in the ITA RSSI mode.
RECEIVED SIGNAL STRENGTH (RSSI) FOR RADIO KEYS - P720E 21-100E
The alarm panel has the ability to display the signal strength of the received signal from individual radio keys.
Please note that this feature is only available if the receiver has the RSSI signal connected. As standard the
RSSI signal is not normally available.
To eliminate confusion when multiple transmitters are in operation, the panel will only display the RSSI level of a
Radio key that is specified at this address. The radio key MUST be enrolled into the panel for this to work. The RSSI
option can be accessed from Client or Installer program modes. In Client mode, the user must have option 7 at
addresses P221E-P240E assigned to their code for them to be allowed to start the RSSI mode.
To display the RSSI level of radio key number 50 press P720E50E.
Now operate the radio key at a distance from the panel then return back to the keypad. The level of the last
transmission from radio key number 50 will be displayed at the keypad with a reading of 1-100%. Received signals
from other radio keys will be ignored by the panel during the RSSI reading.
FIND STORED RADIO CODE PROGRAM LOCATION - P740E
If you wish to confirm where a radio device is stored in memory (eg find what zone number is associated with a radio
device) you can enter in P740E which will put the panel in the “find Radio” mode. The keypad buzzer will beep to
indicate that find mode had been started.
Next, trigger the device you wish to find in memory. When the code has been received and found in memory the
keypad will stop beeping and display the zone or pendant number (eg Z15 = Zone 15, P35 = pendant 35).
If the device being operated is fitted with a tamper switch, you must send the tamper open signal when in find mode
otherwise the panel will ignore the signal.