PROGRAMMING DELAYS & TIMERS
PROGRAMMING DELAYS & TIMERSPROGRAMMING DELAYS & TIMERS
PROGRAMMING DELAYS & TIMERS
OUTPUT RESET TIMES - P901E to P908E
This option sets the duration the output will turn on for until it automatically resets again. A zero means the output
stays on until the trigger is reset at the keypad (latching).
P901E 0-999 Output #1 reset time - Default 600 seconds (10 min)
P902E 0-999 Output #2 reset time - Default 600 seconds (10 min)
P903E 0-999 Output #3 reset time - Default 600 seconds (10 min)
P904E 0-999 Output #4 reset time - Default 600 seconds (10 min)
P905E 0-999 Output #5 reset time - Default 0 (latching)
P906E 0-999 Output #6 reset time - Default 0 (latching)
P907E 0-999 Output #7 reset time - Default 0 (latching)
P908E 0-999 Output #8 reset time - Default 0 (latching)
MAINS FAIL REPORTING DELAY TIME - P909E
The Mains voltage (AC input) must fail for longer than this time before it will report the failure via the dialler.
P909E 0-999 Mains Fail Dialler Report Delay - Default 600 seconds
ZONE ALARM REPORT DELAY TIME - P910E
When the panel is armed and a zone alarm occurs, if there is a value programmed at this address the reporting of the
alarm signal via the dialler will be delayed for this period of time. If the alarm is disarmed before this time expires, no
alarm will be sent. A value of zero means there will be not delay.
P910E 0-999 Zone Alarm Report Delay to Dialler - Default 0 seconds
OUTPUT ON DELAY TIMES - P911E to P918E
When the output is turned on following an alarm, if a value is programmed at this address, the turning on of the
output will be delayed by this time. A value of zero means there will be no delay.
P911E 0-999 Output #1 On delay timer - Default 0 (instant)
P912E 0-999 Output #2 On delay timer - Default 0 (instant)
P913E 0-999 Output #3 On delay timer - Default 0 (instant)
P914E 0-999 Output #4 On delay timer - Default 0 (instant)
P915E 0-999 Output #5 On delay timer - Default 0 (instant)
P916E 0-999 Output #6 On delay timer - Default 0 (instant)
P917E 0-999 Output #7 On delay timer - Default 0 (instant)
P918E 0-999 Output #8 On delay timer - Default 0 (instant)
SUPERVISED RADIO SIGNAL TIMEOUT # 1 - P919E
The panel can monitor wireless detectors that send periodic supervised signals (eg type 5 at addresses P491E-
P510E). Every time a supervised signal is received from a detector the supervisory timer for that detector will be
reset. If the timer expires due to no transmissions from a detector, the panel will generate a supervised failure for that
detector.
P919E 0-255 Supervised Radio Timer # 1 (0-255 minutes) - Default 240 minutes
SUPERVISED RADIO SIGNAL TIMEOUT # 2 - P920E
The panel can monitor wireless detectors that send periodic supervised signals (eg type 5 at addresses P491E-
P510E). Every time a supervised signal is received from a detector the supervisory timer for that detector will be
reset. If the timer expires due to no transmissions from a detector, the panel will generate a supervised failure for that
detector. This timer allows for devices with longer periods between supervised transmissions to be used on the same
system. To use this second timer the zone group must have option 8 turned on at addresses P451E-P470E.
P920E 0-255 Supervised Radio Timer # 2 (0-255 minutes) - Default 240 minutes